on front Microscope inspection |
|
Batch size |
1 |
Excluded materials |
gold (category), copper |
Feature geometry Shape of feature with dimensions characterized by the minimum feature size |
line |
Field geometry Shape of field with dimensions characterized by the maximum field size |
square |
Magnifications |
1000, 500, 200, 100, 25 |
Max field size |
4 mm |
Min feature size |
1 µm |
Sides processed |
either |
Wafer size |
|
Equipment |
Leitz Secolux |
Equipment characteristics: |
Wafer holder Device that holds the wafers during processing. |
delrin |
Wafer materials List of wafer materials this tool can accept (not list of all materials, just the wafer itself). |
silicon, silicon dioxide, alumina |
Wafer thickness List or range of wafer thicknesses the tool can accept |
200 .. 10000 µm |
Extra terms |
Customer agrees that wafers, masks, and other materials
incorporating any process(es) provided by this fabrication site
are to be used solely for non-commercial research
purposes.
|